| VARIABLE DC REGULATED POWER SUPPLIES |
| . |
DC Regulated Power Supplies with Digital Meters to read output voltage and current with overload & short circuit Fuseble Protection |
|
| |
S.No |
Description |
|
| |
PHY-8130 |
0-30V, 0-1A, Power Supply |
|
|
| |
PHY-8130D |
0-30V, 0-1A, Dual Power Supply |
|
| |
PHY-8230 |
0-30V, 0-2A, Power Supply |
|
| |
PHY-8230D |
0-30V, 0-2A, Dual Power Supply |
|
| |
PHY-8230M |
0-30V, 0-2A, +/- 15V@1A
(+/-12V to +/-15V adjustable) 5V @ 5A |
|
| |
PHY-8330 |
0-30V, 0-3A, Power Supply |
|
| |
PHY-8330D |
0-30V, 0-3A, Dual Power Supply |
|
| |
PHY-8530 |
0-30V, 0-5A, Power Supply |
|
| |
PHY-8530D |
0-30V, 0-5A, Dual Power Supply |
|
| |
PHY-81230 |
0-30V, 0-12A, Power Supply |
|
| |
PHY-8160 |
0-60V, 0-1A, Power Supply |
|
| |
PHY-8160D |
0-60V, 0-1A, Dual Power Supply |
|
| |
PHY-8260 |
0-60V, 0-2A, Power Supply |
|
| |
PHY-8260D |
0-60V, 0-2A, Dual Power Supply |
|
| |
PHY-8560 |
0-60V, 0-5A, Power Supply |
|
| |
PHY-81300 |
0-300V/200mA, 0-100V, 6.4V AC/3A |
|
| |
PHY-30DT |
0-30V, 0-1A Dual Tracking/
Independent Selectable |
|
| |
PHY-81030D |
0-30V, 0-10A Dual power supply |
|
| |
PHY-83060 |
0-60V, 0-30A Power supply |
|
| |
PHY-82300 |
0-300V, 0-2A Power Supply |
|
| Fixed DC Power Supplies |
| |
S.No |
Description |
|
| |
PHY-8105 |
5V DC/1A, fixed power supply |
 |
|
| |
PHY-8205 |
5V DC/2A, fixed power supply |
|
| |
PHY-8505 |
5V DC/5A, fixed power supply |
|
| |
PHY-8115 |
+/- 15V DC/1A, fixed power supply |
|
| |
PHY-8126 |
5V DC / , +/- 12V/0.1A, +26V/0.1A |
|
| |
PHY-8226 |
5V DC / 2.5A, +/- 12V/0.1A, +26V/0.1A |
|
|
| 81030D Specifications |
| |
S.No |
Description |
|
| |
Input Voltage |
230V +/- 10% AC, 50Hz |
|
| |
Output Voltage |
0-30V DC, Continuously variable with fine and coarse variation for each channel. |
|
| |
Output Current |
5V DC/5A, fixed power supply 0-10 Amp, Continuously variable with fine and coarse variation for each channel |
|
| |
Mode of operation |
Constant voltage mode: When the load current is less than the current limit set by current control.When the load current limit requirement is more than the current limit set by current control,automatic switch over from constant voltage mode to constant current mode takes place
|
|
| |
Load Regulation |
+/- 0.01% from no load to full load
|
|
| |
Line Regulation |
+/- 0.01% for +/- 10% variation in inputline voltage. |
|
| |
Ripple voltage |
: Less than 1mV rms |
|
| |
Meters |
Two digital meters provided to measure voltage and current with switch selection |
|
| |
Meter Accuracy |
+/- 0.2% of reading, +/- 2 least counts |
|
| |
Protection |
Continuous overload and short circuit protection |
|
|
| 8530 Specifications |
| |
S.No |
Description |
|
| |
Input Voltage |
230V +/- 10% AC, 50Hz |
|
| |
Output Voltage |
0-30V DC, Continuously variable with fine and coarse variation |
|
| |
Output Current |
0-5 Amp, Continuously variable |
|
| |
Mode of operation |
Constant voltage mode: When the load current is less than the current limit set by current control.When the load current limit requirement is more than the current limit set by current control,automatic switch over from constant voltage mode to constant current mode takes place
|
|
| |
Load Regulation |
+/- 0.01% from no load to full load |
|
| |
Line Regulation |
+/- 0.01% for +/- 10% variation in inputline voltage. |
|
| |
Ripple voltage |
: Less than 1mV rms |
|
| |
Meters |
Two digital meters provided to measure voltage and current with switch selection |
|
| |
Meter Accuracy |
+/- 0.2% of reading, +/- 2 least counts |
|
| |
Protection |
Continuous overload and short circuit protection |
|
|
|
 |