VARIABLE DC REGULATED POWER SUPPLIES
.

DC Regulated Power Supplies with Digital Meters to read output voltage and current with overload & short circuit Fuseble Protection

  S.No Description  
  PHY-8130 0-30V, 0-1A, Power Supply
 
  PHY-8130D 0-30V, 0-1A, Dual Power Supply  
  PHY-8230 0-30V, 0-2A, Power Supply  
  PHY-8230D 0-30V, 0-2A, Dual Power Supply  
  PHY-8230M

0-30V, 0-2A, +/- 15V@1A
(+/-12V to +/-15V adjustable) 5V @ 5A

 
  PHY-8330

0-30V, 0-3A, Power Supply

 
  PHY-8330D

0-30V, 0-3A, Dual Power Supply

 
  PHY-8530 0-30V, 0-5A, Power Supply  
  PHY-8530D

0-30V, 0-5A, Dual Power Supply

 
  PHY-81230

0-30V, 0-12A, Power Supply

 
  PHY-8160

0-60V, 0-1A, Power Supply

 
  PHY-8160D

0-60V, 0-1A, Dual Power Supply

 
  PHY-8260 0-60V, 0-2A, Power Supply  
  PHY-8260D

0-60V, 0-2A, Dual Power Supply

 
  PHY-8560

0-60V, 0-5A, Power Supply

 
  PHY-81300

0-300V/200mA, 0-100V, 6.4V AC/3A

 
  PHY-30DT 0-30V, 0-1A Dual Tracking/ Independent Selectable  
  PHY-81030D

0-30V, 0-10A Dual power supply

 
  PHY-83060

0-60V, 0-30A Power supply

 
  PHY-82300 0-300V, 0-2A Power Supply  
   Fixed DC Power Supplies
  S.No Description  
  PHY-8105 5V DC/1A, fixed power supply  
  PHY-8205 5V DC/2A, fixed power supply  
  PHY-8505

5V DC/5A, fixed power supply

 
  PHY-8115

+/- 15V DC/1A, fixed power supply

 
  PHY-8126

5V DC / , +/- 12V/0.1A, +26V/0.1A

 
  PHY-8226

5V DC / 2.5A, +/- 12V/0.1A, +26V/0.1A

 
   81030D Specifications
  S.No Description  
  Input Voltage 230V +/- 10% AC, 50Hz  
  Output Voltage 0-30V DC, Continuously variable with fine and coarse variation for each channel.  
  Output Current

5V DC/5A, fixed power supply 0-10 Amp, Continuously variable with fine and coarse variation for each channel

 
  Mode of operation

Constant voltage mode: When the load current is less than the current limit set by current control.When the load current limit requirement is more than the current limit set by current control,automatic switch over from constant voltage mode to constant current mode takes place

 
  Load Regulation

+/- 0.01% from no load to full load

 
  Line Regulation

+/- 0.01% for +/- 10% variation in inputline voltage.

 
  Ripple voltage : Less than 1mV rms  
  Meters
Two digital meters provided to measure voltage and current with switch selection
 
  Meter Accuracy +/- 0.2% of reading, +/- 2 least counts  
  Protection Continuous overload and short circuit protection  
   8530 Specifications
  S.No Description  
  Input Voltage 230V +/- 10% AC, 50Hz  
  Output Voltage 0-30V DC, Continuously variable with fine and coarse variation  
  Output Current

0-5 Amp, Continuously variable

 
  Mode of operation

Constant voltage mode: When the load current is less than the current limit set by current control.When the load current limit requirement is more than the current limit set by current control,automatic switch over from constant voltage mode to constant current mode takes place

 
  Load Regulation

+/- 0.01% from no load to full load

 
  Line Regulation

+/- 0.01% for +/- 10% variation in inputline voltage.

 
  Ripple voltage : Less than 1mV rms  
  Meters
Two digital meters provided to measure voltage and current with switch selection
 
  Meter Accuracy +/- 0.2% of reading, +/- 2 least counts  
  Protection Continuous overload and short circuit protection  
Copywrites@2004-2005
www.physitechelectronics.com
Website Designed and Hosted by JB Software Solutions